The label 4:2:0 tells you how many chroma samples are retained relative to luma, but it does not completely specify their spatial positions. Two grids with the same sample counts can place chroma differently. A conversion must account for those positions when reconstructing color at the luma grid.
Keep the sample grid and its origin
Imagine luma samples on integer coordinates. A chroma grid sampled every two luma positions can be shifted horizontally or vertically while retaining exactly the same sample count. The dimensions alone will not reveal that shift. Microsoft’s rendering guidance illustrates distinct MPEG-1 and MPEG-2 forms of 4:2:0 and identifies the MPEG-2 form as its Windows preference. That platform-specific default should not become an assumption about every coded format.
Read an explicit codec declaration
AV1 provides a concrete example through chroma_sample_position. Its vertical position declaration places chroma horizontally alongside the first luma sample and vertically between two luma samples. Its colocated declaration instead places chroma at the first luma sample. Both describe subsampled data; the difference is location. The unknown value preserves uncertainty rather than authorizing a parser to invent a precise grid from the sampling ratio alone.
Understand a registration error
Suppose a converter treats a vertically offset chroma sample as though it were colocated with luma. The interpolation then assigns color information to the wrong vertical position. Around a sharp colored edge, the reconstructed color boundary can become displaced relative to brightness detail. This is a conceptual mechanism, not proof that every colored fringe has that cause. Filters, scaling and the original image can produce other edge appearances.
Preserve the declaration through processing
A conversion report should keep sampling ratio, chroma location, scan structure and interpolation method together. Microsoft’s example upsampling discussion explicitly identifies phase offsets and limits its worked method to progressive pictures; interlaced conversion needs additional treatment. Simply expanding a 4:2:0 buffer into more samples does not establish correct registration. When comparing two processing paths, first determine whether they use the same grid interpretation, then compare edge positions under otherwise matching conditions.